存储断电关机再开机后报错

Aug 4 11:20:26 MSA2040 APPSV[2306] WARNING A disk that was part of a disk group is down. A previously detected disk is no longer present. (disk group: dg03, SN: 00c0ff26313000009e2a0b5600000000) (disk: channel: 0, ID: 75, SN: W8GS31BX, enclosure: 2, slot: 12)
Aug 4 11:20:27 MSA2040 APPSV[2306] ERR There is a problem with a FRU. (FRU type: disk, enclosure: 2, slot: 12, device ID: 76, vendor: , product ID: , SN: W8GS31BX, version: , related event serial number: A13582, related event code: 8)
Aug 4 11:20:28 MSA2040 APPSV[2306] CRIT A disk group is critical. (disk group: dg03, SN: 00c0ff26313000009e2a0b5600000000)
Aug 4 11:20:28 MSA2040 APPSV[2306] WARNING A disk that was part of a disk group is down. A previously detected disk is no longer present. (disk group: dg02, SN: 00c0ff2642920000392a0b5600000000) (disk: channel: 0, ID: 79, SN: W8GRNDSX, enclosure: 2, slot: 16)
Aug 4 11:20:29 MSA2040 APPSV[2306] ERR There is a problem with a FRU. (FRU type: disk, enclosure: 2, slot: 16, device ID: 80, vendor: , product ID: , SN: W8GRNDSX, version: , related event serial number: B4123, related event code: 8)
Aug 4 11:20:30 MSA2040 APPSV[2306] CRIT A disk group is critical. (disk group: dg02, SN: 00c0ff2642920000392a0b5600000000)
Aug 4 11:20:31 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a power supply. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) power supply LEFT, power supply status: DC failure, AC failure
Aug 4 11:20:32 MSA2040 APPSV[2306] ERR There is a problem with a FRU. (FRU type: A/C PSU, Left, enclosure: 1, product ID: 592267-002, SN: 7CE505W863, version: D1, related event serial number: A13586, related event code: 551)
Aug 4 11:20:33 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a voltage sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) voltage sensor for Voltage 12V Loc: left-PSU, sensor status: N/A, voltage: 0.28 V
Aug 4 11:20:33 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a voltage sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) voltage sensor for Voltage 5V Loc: left-PSU, sensor status: N/A, voltage: 0.12 V
Aug 4 11:20:34 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a voltage sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) voltage sensor for Voltage 3.3V Loc: left-PSU, sensor status: N/A, voltage: 0.25 V
Aug 4 11:20:35 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a current sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) current sensor for Current 12V Loc: left-PSU, sensor status: N/A, current: 0.36 A
Aug 4 11:20:35 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a current sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) current sensor for Current 5V Loc: left-PSU, sensor status: N/A, current: 0.2 A
Aug 4 11:20:36 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a power supply. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) power supply LEFT, power supply status: DC failure, AC failure
Aug 4 11:20:36 MSA2040 APPSV[2306] ERR There is a problem with a FRU. (FRU type: A/C PSU, Left, enclosure: 1, product ID: 592267-002, SN: 7CE505W863, version: D1, related event serial number: B4127, related event code: 551)
Aug 4 11:20:38 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a voltage sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) voltage sensor for Voltage 12V Loc: left-PSU, sensor status: N/A, voltage: 1.93 V
Aug 4 11:20:39 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a voltage sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) voltage sensor for Voltage 5V Loc: left-PSU, sensor status: N/A, voltage: 0.84 V
Aug 4 11:20:41 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a voltage sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) voltage sensor for Voltage 3.3V Loc: left-PSU, sensor status: N/A, voltage: 1.04 V
Aug 4 11:20:41 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a current sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) current sensor for Current 12V Loc: left-PSU, sensor status: N/A, current: 1.4 A
Aug 4 11:20:42 MSA2040 APPSV[2306] ERR An Enclosure Management Processor (EMP) reported an alert condition on a current sensor. Type: fault. (enclosure: 1, WWN: 500C0FF01EA6343C) current sensor for Current 5V Loc: left-PSU, sensor status: N/A, current: 0.46 A
Aug 4 11:20:56 MSA2040 APPSV[2306] WARNING Unwritable write-back cache data exists for a volume. (disk group: unknown name, volume: unknown name, SN: 00c0ff2631300000dbf8375601000000) It comprises 33% of cache space.
Aug 4 11:20:56 MSA2040 APPSV[2306] WARNING Unwritable write-back cache data exists for a volume. (disk group: unknown name, volume: unknown name, SN: 00c0ff263130000048e10b5601000000) It comprises 29% of cache space.
Aug 4 11:20:57 MSA2040 APPSV[2306] WARNING Unwritable write-back cache data exists for a volume. (disk group: unknown name, volume: unknown name, SN: 00c0ff26313000007df9375601000000) It comprises 35% of cache space.
Aug 4 11:20:57 MSA2040 APPSV[2306] WARNING Unwritable write-back cache data exists for a volume. (disk group: unknown name, volume: unknown name, SN: 00c0ff264292000046f9375601000000) It comprises 35% of cache space.
Aug 4 11:20:58 MSA2040 APPSV[2306] WARNING Unwritable write-back cache data exists for a volume. (disk group: unknown name, volume: unknown name, SN: 00c0ff2642920000ccf9375601000000) It comprises 33% of cache space.
Aug 4 11:20:58 MSA2040 APPSV[2306] WARNING Unwritable write-back cache data exists for a volume. (disk group: unknown name, volume: unknown name, SN: 00c0ff2642920000e47a3f5d01000000) It comprises 28% of cache space.
Aug 4 11:57:15 MSA2040 APPSV[2314] WARNING A disk that was part of a disk group is down. A previously detected disk is no longer present. (disk group: dg02, SN: 00c0ff2642920000392a0b5600000000) (disk: channel: 0, ID: 79, SN: W8GRNDSX, enclosure: 2, slot: 16)
Aug 4 11:57:16 MSA2040 APPSV[2314] ERR There is a problem with a FRU. (FRU type: disk, enclosure: 2, slot: 16, device ID: 80, vendor: HP , product ID: EG0900FBVFQ , SN: W8GRNDSX, version: HPDC, related event serial number: B4171, related event code: 8)
Aug 4 11:57:16 MSA2040 APPSV[2314] CRIT A disk group is critical. (disk group: dg02, SN: 00c0ff2642920000392a0b5600000000)
Aug 4 11:57:17 MSA2040 APPSV[2314] WARNING A scrub-disk-group job was aborted because of an internally detected condition such as a failed disk. (number of parity or mirror mismatches found: 0, number of media errors found: 0) (disk group: dg02, SN: 00c0ff2642920000392a0b5600000000)
Aug 4 11:57:20 MSA2040 APPSV[2314] WARNING There is no dedicated or global spare that can be used for reconstructing this disk group. If a disk in the disk group fails, reconstruction cannot start automatically. (disk group: dg02, SN: 00c0ff2642920000392a0b5600000000)
Aug 4 11:57:23 MSA2040 APPSV[2314] WARNING A disk that was part of a disk group is down. A previously detected disk is no longer present. (disk group: dg03, SN: 00c0ff26313000009e2a0b5600000000) (disk: channel: 0, ID: 75, SN: W8GS31BX, enclosure: 2, slot: 12)
Aug 4 11:57:23 MSA2040 APPSV[2314] ERR There is a problem with a FRU. (FRU type: disk, enclosure: 2, slot: 12, device ID: 76, vendor: HP , product ID: EG0900FBVFQ , SN: W8GS31BX, version: HPDC, related event serial number: A13629, related event code: 8)
Aug 4 11:57:24 MSA2040 APPSV[2314] CRIT A disk group is critical. (disk group: dg03, SN: 00c0ff26313000009e2a0b5600000000)
Aug 4 11:57:26 MSA2040 APPSV[2314] WARNING A scrub-disk-group job was aborted because of an internally detected condition such as a failed disk. (number of parity or mirror mismatches found: 0, number of media errors found: 0) (disk group: dg03, SN: 00c0ff26313000009e2a0b5600000000)